New Structure: - 01-NETWORK-MAP.md - Network topology, IPs, Docker networks, services - 02-SERVICES-CRITICAL.md - DNS, Auth, Routing (P0/P1 services) - 03-SERVICES-OTHER.md - All non-critical services - 04-HARDWARE-INVENTORY.md - Physical devices and specs - 05-CHANGELOG.md - Major events only New Folders: - docs/archive/ - Legacy docs (read-only reference) - docs/wip/ - Planned changes and ideas - UPGRADE-2026-HARDWARE.md - N5 Air + N100 migration plan - GITOPS-CONTAINERS.md - Phase 2 container GitOps Changes: - Moved all 22 legacy docs to archive/ - Consolidated container IPs, physical map, and services into single network map - Extracted critical vs non-critical service classification - Simplified changelog to major events only Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
6.1 KiB
6.1 KiB
Hardware Upgrade Plan 2026
Status: 📋 PLANNED Target: Q1 2026 Author: Kaloyan
Overview
Migration from single-server architecture to dual-server with survival capabilities.
Device Naming Convention
| Name | Hardware | Role | Notes |
|---|---|---|---|
| XTRM-U | Current NAS chassis | Current production | Will be decommissioned |
| XTRM-N5 | Minisforum N5 Air | New production NAS | Inherits XTRM-U storage, OS, services + new NVMe pool |
| XTRM-N1 | N100 ITX (XTRM-U board) | Survival node | Same 4x2.5GbE NIC, 1U 10" case, no HDDs |
Hardware Specifications
XTRM-N5 (Minisforum N5 Air) - Production Server
| Component | Specification |
|---|---|
| CPU | Intel N95/N100 or similar |
| RAM | TBD |
| Storage (Fast) | 3x Samsung 990 EVO Plus 1TB (NVMe ZFS RAID-Z1) |
| Storage (Capacity) | Existing 3.5" HDD Array (from XTRM-U) |
| Network | 10GbE Primary + 5GbE Secondary |
| OS | Unraid 7 (internal boot from NVMe pool) |
XTRM-N1 (N100 ITX) - Survival Node
| Component | Specification |
|---|---|
| Board | XTRM-U motherboard (4x 2.5GbE Intel NICs) |
| Chassis | 1U 10" Rackmount (modular/3D printed) |
| Storage | 2x Fikwot FX501Pro 512GB (NVMe mirror) |
| Power | PicoPSU + 12V External Brick |
| OS | Proxmox VE or Debian |
Migration Flow
XTRM-U (Current State)
├── Hardware (board, 4x2.5GbE) ──────────────► XTRM-N1 (1U 10" case)
│ └── New role: Survival node
│ └── New storage: 2x Fikwot 512GB
│
├── Storage (3.5" HDDs) ─────────────────────► XTRM-N5
├── OS (Unraid + config) ────────────────────► XTRM-N5
├── Services (containers) ───────────────────► XTRM-N5
│ └── New: Samsung NVMe pool
│
└── Chassis ─────────────────────────────────► Retired
Post-Migration Architecture
XTRM-N1 (Survival Node)
Purpose: Keep network alive if production server is offline
| Service | Purpose | Priority |
|---|---|---|
| OPNsense | Firewall/Router (replaces HAP1 routing) | P0 |
| AdGuard Home | DNS | P0 |
| Vaultwarden | Password manager | P0 |
| Authentik (replica) | SSO backup | P1 |
XTRM-N5 (Production Server)
Purpose: Primary services and storage
| Service | Purpose | Priority |
|---|---|---|
| Nextcloud | File sync/storage | P1 |
| Plex | Media streaming | P2 |
| Authentik (primary) | SSO | P1 |
| Gitea | Git hosting | P2 |
| Woodpecker CI | CI/CD | P2 |
| NetBox | Network documentation | P2 |
| All other services | Various | P3 |
Rack Layout (Post-Migration)
10" Rack (9U)
| U | Device | Notes |
|---|---|---|
| U9 | Shelf + ISP Gateway | Unchanged |
| U8 | PP2 (12-port) | Unchanged |
| U7 | Shelf + ZX1 (or CRS310) | Future: upgrade to CRS310 |
| U6 | XTRM-N1 | NEW: Survival node |
| U5 | (empty) | |
| U4 | (XTRM-N5 continued) | |
| U3 | (XTRM-N5 continued) | |
| U2 | (XTRM-N5 continued) | |
| U1 | XTRM-N5 | NEW: Production server |
Software Configuration
XTRM-N5: Unraid 7 Features
-
Internal Boot Pool
- Use "Add Bootable Pool" feature
- ZFS RAID-Z1 with 3x Samsung 990 EVO Plus
- Partition 1: 8GB (OS boot)
- Partition 2: ~1.8TB usable (data/containers)
- Remove USB boot stick
-
Storage Pools
- nvme_pool: 3x Samsung 990 EVO Plus (~1.8TB usable)
- hdd_pool: Existing 3.5" HDDs (capacity tier)
XTRM-N1: Proxmox Configuration
-
Storage
- ZFS mirror: 2x Fikwot 512GB
- Boot + VMs + Containers
-
VMs/Containers
- OPNsense VM (if routing moves here)
- AdGuard LXC
- Vaultwarden LXC
- Authentik LXC (replica)
Network Changes
Current (HAP1 as router)
Internet → HAP1 (Router) → ZX1 → XTRM-U
→ CSS1 → Room outlets
Option A: Keep HAP1 as Router
Internet → HAP1 (Router) → ZX1 → XTRM-N5
↓ → XTRM-N1 (services only)
→ CSS1 → Room outlets
Option B: Move Routing to XTRM-N1
Internet → HAP1 (Bridge) → XTRM-N1 (OPNsense) → ZX1 → XTRM-N5
→ CSS1 → Rooms
Decision: TBD based on performance testing
Thermal Management
| Strategy | Implementation |
|---|---|
| Samsung NVMe in N5 | "Thermal Champions" - run cooler than Fikwot |
| Physical spacing | 1U gap between XTRM-N1 and XTRM-N5 |
| Active cooling | Exhaust fans tied to drive temp sensors |
| HDD hibernation | Aggressive spindown, NVMe handles active I/O |
Future Milestone: CRS310 Upgrade
When budget allows, replace ZX1 with MikroTik CRS310-8G+2S+IN:
| Feature | Benefit |
|---|---|
| 10G DAC to CSS326 | Proper backbone |
| L3 offloading | Inter-VLAN routing off HAP1 |
| 8x 2.5G ports | All servers at full speed |
Migration Checklist
Pre-Migration
- Order XTRM-N5 hardware
- Order 3x Samsung 990 EVO Plus 1TB
- Order 2x Fikwot FX501Pro 512GB
- Design/print 1U 10" chassis for N1
- Order PicoPSU + 12V brick
XTRM-N1 Setup (First)
- Extract XTRM-U motherboard
- Install in 1U chassis
- Install Fikwot NVMe drives
- Install Proxmox VE
- Deploy survival services (AdGuard, Vaultwarden)
- Test network survival (unplug XTRM-U)
XTRM-N5 Setup
- Unbox and install Samsung NVMe drives
- Create ZFS boot pool
- Migrate Unraid config from USB
- Transfer HDD array
- Verify all services running
- Update DNS/IPs as needed
Post-Migration
- Update NetBox with new devices
- Update documentation
- Decommission old XTRM-U chassis
- Performance testing
- Thermal monitoring
Related Documents
GITOPS-CONTAINERS.md- Phase 2: Container configuration in Git